♦ Main Features
Stable Running
AquaPower can run stably at ambient temperature from -15°C to 43°C, satisfying the needs in large range of regions. It can reliably provide constant pool water temperature for both heating and cooling on every commercial occasion.
High Efficiency
High efficiency during running in different conditions is ensured by comprehensive refrigerant system design, twisted titanium and finned-tube heat exchangers both with large heat exchange area, precise EEV controlling and intelligent defrosting.
Large Capacity
AquaPower series is with large capacity for pool with volume up to around 1100m³, more competitive for application of big pools, such as hotels, aqua parks, gyms and so on.
♦ Parameters
Model |
BPF-650 |
BPF-1300 |
BPF-2150 |
|
Advised Pool Volume |
m³ |
180~350 |
350~700 |
600~1100 |
Performance Condition (Air 27 °C / Water 26 °C / Humid. 80%) |
||||
Heating Capacity |
kW |
65 |
130 |
215 |
Heating Power Input |
kW |
10.81 |
21.59 |
35.71 |
COP | W/W |
6.01 |
6.02 |
6.02 |
Performance Condition (Air 15 °C / Water 26 °C / Humid. 70%) |
||||
Heating Capacity |
kW |
48 |
98 |
160 |
Heating Power Input |
kW |
9.21 |
18.84 |
30.76 |
COP | W/W | 5.21 | 5.20 | 5.20 |
Performance Condition (Air 35 °C / Water 30 °C / Humid. 40%) |
||||
Cooling Capacity |
kW |
33 |
60 | 95 |
Cooling Power Input |
kW |
13.20 |
23.81 |
37.84 |
EER | W/W |
2.50 |
2.52 |
2.51 |
Power Supply |
V/Ph/Hz |
380V/3 Ph/50Hz |
||
Sound Pressure at 1 m |
dB(A) |
63 |
73 |
76 |
Sound Pressure at 10 m |
dB(A) |
43 |
53 | 56 |
Water Connection |
mm | 63 | 110 | 110 |
Water Volume |
m³/h |
28 |
56 | 93 |
Water Pressure Drop (max) |
kPa | 15 | 16 | 20 |
Net Dimensions (L×W×H) |
mm |
1750×850×1750 |
1995×900×2000 |
2355×1105×2400 |
Net Weight |
kg |
350 |
650 | 1300 |
Operating Air Temp. |
°C |
Heating: -15~43 °C, Cooling: 30~43 °C |
||
Operating Water Temp. |
°C |
Heating: 9~40 °C, Cooling: 28~35 °C |
||
Refrigerant |
- |
R410A |